Furnace problems RV: Diagnose failures fast, avoid cold-night lockouts, save money
Furnace problems in RVs: what’s going wrong, why it matters, and how to protect your trip and wallet
AI-powered research tools have systematically collected and analyzed public information to produce this report. Furnace failures are among the most disruptive and stressful RV issues because they strike when you need heat the most, often overnight and far from service help. This investigation organizes widespread owner complaints, traces common root causes, and offers step-by-step actions you can take to diagnose issues, insist on safe repairs, and reduce repeat failures.
We examined consumer reports across forums, complaint boards, and owner groups, and we found clear patterns: many “furnace problems” are not just a single part failure but a chain failure involving battery voltage, propane pressure, airflow restrictions, control boards, and installation shortcuts. This report focuses on practical accountability and specific steps you can take, whether you have a traditional propane forced-air furnace (common brands include Suburban and Atwood/Dometic), a newer high-efficiency unit (e.g., Truma VarioHeat), or a diesel hydronic system (Aqua-Hot/Hydro-Hot/Webasto-style).
Before you dive in, a quick note on safety: gas appliances can create fire and carbon monoxide hazards. If you ever smell gas, see soot, or suspect a cracked heat exchanger, stop using the furnace and get professional help immediately. If you’ve experienced recurring furnace problems, tell us what happened so other RV owners can learn.
Where to hear unfiltered owner experiences and find real-world fixes
Owner communities are the fastest way to validate a problem you’re seeing and to learn what’s normal for your model. For unbiased crowdsourced data points, we recommend these starting points:
- Find RV brand Facebook groups about Furnace problems RV (via Google search) — Join multiple groups, not just your brand, to compare how different rigs handle identical furnace issues.
- Reddit r/rvs owner threads on Furnace problems RV — Search symptoms (“short cycling,” “sail switch,” “no ignition”) for quick community triage.
If you prefer an independent inspection before buying or after repeated repairs, consider a third-party check: search “RV Inspectors near me” and hire someone who brings a manometer, multimeter, and CO analyzer to verify the entire furnace system, not just swap parts.
How RV furnaces actually work (and why they fail)
Propane forced-air furnaces in most towables and motorhomes
Most RV furnaces run on propane for heat and 12V DC for controls and the blower. Typical sequence of operation:
- Thermostat calls for heat, sending 12V to the furnace board.
- Blower motor spins up. When airflow is sufficient, the sail switch closes.
- Ignition sequence starts: the gas valve opens, the igniter sparks, and the burner lights.
- Flame sensor feedback proves flame; the furnace continues heating until setpoint is reached.
- Limit switch/ECO protects against overheating from blocked ducts or restricted airflow; if tripped, the burner shuts off.
Failures at any step (low voltage, faulty switches, blocked airflow, bad board, poor propane supply) can cascade into lockouts or repeated short cycling. Many owner-reported “bad furnaces” are actually battery-voltage or ducting issues weakening the entire sequence.
Diesel hydronic systems (Aqua-Hot/Hydro-Hot/Webasto-style)
These use a diesel burner (or electric element) to heat a glycol-water loop that feeds fan-coil heat exchangers throughout the coach and typically provides on-demand domestic hot water. They’re comfortable and quiet but have their own failure modes: coked burners, dirty nozzles, air in lines, circulation pump failures, and altitude problems. While different from propane furnaces, the same fundamentals apply: combustion air, fuel quality/pressure, and good ventilation are non-negotiable.
Top furnace complaints we found, decoded into causes and solutions
1) Blower runs, no ignition
- Low 12V voltage under load — A weak battery or poor wiring drops voltage when the blower starts, preventing the sail switch from closing. Symptoms: lights dim when furnace starts, furnace clicks but no flame. Solution: measure voltage at the furnace board during startup; you want stable 12V+ under load. Charge/replace batteries, service connections, and verify the converter/charger is delivering ~13.6V on shore power.
- Airflow too low to close sail switch — Crushed ducts, blocked return air, or dirty blower wheel. Solution: clear returns (under bed/cabinets), open registers, inspect ducts near tight cabinetry, and clean blower. Many owners find a single pinched duct starves the furnace.
- LP supply problem — Tank too low, regulator failing, or another appliance hogging gas. Solution: confirm propane tank level and that the regulator delivers nominal RV pressure (often ~11” water column) under load; a tech can test with a manometer.
- Igniter/electrode issues — Incorrect gap or cracked insulator. Solution: clean and gap per the furnace manufacturer’s spec; replace if worn.
- Control board failure — Boards can fail intermittently with heat/cold cycles. Solution: board test or substitution with a known-good board; consider known-quality replacements from reputable suppliers.
2) Short cycling: lights, heats briefly, shuts off, repeats
- Blocked outlets or return air can trip the high-limit switch. Quick tell: the blower keeps running after burner stops, then tries again. Solution: open all registers, check for duct kinks, remove stored items blocking returns. Don’t close too many vents to “force heat” to one room.
- Thermostat location and settings — If the thermostat sits in direct warm airflow or near the furnace cabinet, it will satisfy prematurely. Solution: redirect vents, relocate thermostat, or shield it from direct heat.
- Over-firing or bad regulator — Sooting and rumble may accompany. Solution: professional LP pressure check and burner inspection.
3) Furnace won’t start at all
- Blown fuse or loose ground — Furnace needs clean DC power and a solid ground bond. Solution: check the 12V fuse panel, inspect furnace ground.
- Thermostat or control wiring — Loose connections behind the wall or at the furnace can kill the call-for-heat signal. Solution: verify continuity and secure splices; replace suspect thermostats with proper RV-compatible models.
- Safety lockout — After multiple failed attempts, many furnaces lock out until power is cycled. Solution: turn the thermostat off, wait, restore power, and attempt a single restart after you’ve addressed probable causes.
4) Soot, rumbling, or smoky exhaust (high risk)
- Immediate action: stop using the furnace and ventilate. Install or test your CO detector now.
- Likely culprits: improper combustion mix, damaged burner tube, insects/debris in combustion chamber, or a cracked heat exchanger (rare but serious).
- Solution: professional inspection. Soot means incomplete combustion and can lead to CO inside the cabin via leaks or return-air paths.
5) Hydronic heat: burner runs, but coach still cold
- Air in loops or weak circulation pump — You’ll feel some coils hot and others stone-cold. Solution: bleed system per manufacturer procedure; test/replace pumps.
- Diesel burner coking — Nozzle/combustion chamber fouling from fuel quality or long idle periods. Solution: annual service (nozzle, filter, combustion chamber cleaning); altitude kits or adjustments where available.
- Thermostat/zone relays — If hot glycol is circulating but fans don’t run, look at zone control relays/fuses.
Have you seen a different pattern? Add your furnace symptom and what fixed it so others can compare notes.
What changed recently: post-boom quality variations and newer tech
- Post-2020 production surge: Owners reported more fit-and-finish issues during and after the demand boom, including poorly secured ducts, undersized return-air paths, and wiring shortcuts. Many “new” furnace failures traced back to installation flaws rather than defective components.
- Control electronics: Modern boards are more sensitive to low voltage and electrical noise. Mixed-battery banks, weak grounds, and corroded connectors increasingly show up as furnace “mystery” problems.
- High-efficiency units entering mainstream: Brands like Truma have brought quieter, modulating furnaces with more even heat. They’re less forgiving of installation errors and require careful ducting and intake/exhaust clearances per spec.
- Hydronic refinement: Better diagnostics and service kits exist, but burner maintenance remains essential, especially for high-altitude or cold-soak usage.
Safety first: checks you should do today
- Test your CO and LP detectors monthly. Replace CO detectors at manufacturer’s recommended life (often 5–7 years). Ensure LP detectors are hardwired and not disabled for “nuisance” alarms.
- Inspect intake/exhaust ports before every trip. Use purpose-made insect screens for the furnace exhaust and water heater—but never homemade coverings that restrict airflow.
- Keep returns clear. Under-bed, under-dinette, or closet returns get blocked by gear and bedding more often than people realize.
- Don’t ignore soot or unusual rumbling. That’s a stop-use-now condition.
The voltage trap: why your furnace fails on cold nights
Many owners assume that shore power or a running generator means “the furnace has power.” In reality, RV furnaces are 12V devices. When the blower kicks on, it draws significant current; if the converter or batteries can’t keep voltage steady, the sail switch may not close and the board won’t allow ignition. Classic scenario: everything works fine by day, then temperatures drop, batteries sag, and the furnace refuses to light at 2 a.m.
- What to measure: voltage at the furnace board during blower startup. Aim for a stable 12V+ under load. Anything dipping near 10.5–11V can cause failures.
- Fixes: fully charge batteries, clean/tighten grounds, verify the converter produces ~13.4–13.8V, and upgrade undersized wiring runs if voltage drop is significant.
- Lithium note: if using LiFePO4 with low-temperature protection, be aware that charging may be restricted in the cold. Ensure a warm battery compartment or a cold-rated battery system to avoid unexpected low-voltage behavior.
Propane system realities: pressure, regulators, and contamination
LP issues masquerade as furnace defects. Regulators weaken, tanks can carry oil-like residues, and lines can accumulate moisture or debris. Under-load pressure is what matters.
- Regulator health: If your stove flames waver when multiple appliances run, suspect your regulator. A manometer test during furnace startup and operation is the gold standard.
- Dual-tank auto-changeover valves: They can stick or partially obstruct flow. Manually switch sides to test.
- Appliance interaction: Water heaters and fridges starting simultaneously can pull pressure down. Stagger your appliance starts if you’re on the edge.
Not sure? A mobile RV tech or inspector can run a pressure and leak test. If you’ve had propane-side surprises, post your test results and what solved it for other owners researching similar issues.
Airflow and ducting: the hidden saboteur
We consistently find that restricted air movement causes short cycling, shutdowns, hot/cold zones, and noisy operation. RV cabinets are tight; every bend matters.
- Return air: Ensure a direct, unobstructed path back to the furnace. Add grill cutouts if your manufacturer undersized return paths (many owners do).
- Duct layout: Replace crushed flex duct; avoid 90-degree kinks; use smooth-radius elbows where you can.
- Registers: Avoid closing too many vents. The furnace expects a minimum airflow; choking it will trip the limit switch.
- Filter myth: Most RV furnaces do not use return filters because filters can restrict airflow. If you add one for pet hair/dust, oversize it and monitor temperatures carefully.
Thermostats and controls: analog vs. digital quirks
- Analog 2-wire thermostats are simple but can drift. Replacements must be 12V-compatible; not all home thermostats are suitable.
- Multi-zone or networked systems (e.g., some Dometic setups) introduce communication cables and control modules. A single loose connector can take down the furnace zone while A/C still works.
- Calibration and location matter. If your thermostat sits in a sunlit spot or near a heat duct, expect early shutoff.
Common parts that fail (and realistic costs)
Prices vary by brand, model, and labor rates, but these ballpark figures help you budget:
- Sail switch: $15–$40 part; 1–2 hours labor depending on access.
- High-limit switch: $20–$60 part; often paired with airflow fixes.
- Igniter/electrode set: $25–$80; careful gapping needed.
- Control board: $120–$250; labor 0.5–1.5 hours; ensure proper model.
- Blower motor: $200–$400; 2–3 hours labor; check wheel balance and clean housing.
- Complete furnace replacement: $800–$1,500 for common models plus installation and ducting adjustments.
- Hydronic annual service: $300–$800 typical for nozzle, filter, cleaning; deeper repairs cost more.
Pro tip: when replacing a board or motor, correct the underlying cause (low voltage, bad regulator, airflow restriction) to avoid repeating the repair.
Altitude, weather, and storage effects
- High altitude: Thin air changes combustion. Some systems struggle above ~5,000–7,000 feet. Hydronic burners may need specific altitude adjustments or kits; most propane furnaces are not field-adjustable, so ensure the installation is perfect and keep ducts clean to maximize margin.
- Cold-soak starts: After a long cold soak, batteries are weaker and fuel systems sluggish. Pre-warm batteries if possible, and run the furnace early to avoid a 2 a.m. first start.
- Off-season storage: Mud daubers and spiders love burner tubes and vents. Use purpose-built screens and inspect before first start each season.
Installation quality: the thorn behind many “new RV” furnace issues
Across owner reports, we found repeated patterns in new rigs:
- Crimped ducts behind drawers where a staple or screw collapsed flex.
- Starved return-air paths because a decorative panel blocked airflow.
- Loose grounds and splices in the furnace 12V supply line causing intermittent dropouts.
Accountability tip: when under warranty, insist the dealer documents voltage measured at the furnace under load, duct temperatures, and propane pressure. Ask for photos of duct corrections. If your service order only says “replaced board,” you may be headed for a repeat failure.
Recalls, bulletins, and how to check your rig
Recalls related to heating can appear under the RV manufacturer’s name, not just the appliance brand. Search by your RV’s brand and model year, then review the recall descriptions for anything related to heating, propane, or interior air quality. Start here:
Also consider browsing owner reports and complaint boards for patterns related to your brand and furnace type. If you uncover a safety defect trend not addressed by a bulletin, file a safety complaint. Your report can help trigger broader action.
What to test before you buy (new or used)
At the dealer lot or seller’s driveway
- Run the furnace for 30–45 minutes from a cold start. Short “demo puffs” won’t expose issues.
- Measure voltage at the furnace during startup and mid-run. Verify the converter is charging and voltage remains stable.
- Open cabinets and look at ducts for kinks or sharp bends. Confirm returns aren’t blocked by decorative panels.
- Check for soot at the exhaust. None should be present on a properly running propane furnace.
- Listen for short cycling and confirm all registers blow warm air.
On used hydronic systems
- Ask for service records (nozzle/filter changes, burner cleanings).
- Run all zones to verify circulation and fan operation.
- Inspect around the boiler unit for leaks, soot, or diesel odors.
Not comfortable evaluating this yourself? Consider a pre-purchase inspection: find a certified RV inspector who can document furnace performance with tools.
Step-by-step DIY triage (before you schedule service)
Basic checks you can do safely
- Battery and connectors: fully charge, then clean and tighten all 12V connections and grounds. Re-test furnace.
- Return air and registers: open everything; remove obstructions; verify airflow at each register.
- Exhaust/intake: remove any insect nests; ensure purpose-built screens are clean.
- Thermostat wiring: remove the thermostat from the equation by temporarily jumping the furnace control terminals (consult your model’s wiring diagram). If it runs, the thermostat or its wiring may be bad.
Advanced checks (best for experienced DIYers)
- Igniter inspection: verify electrode gap and no cracks in ceramic.
- Sail switch test: check for mechanical freedom and proper closure during blower operation.
- LP pressure under load: with a manometer, verify the regulator maintains pressure at the appliance while running.
If you’re not equipped or confident, stop at the basic checks and call a qualified RV tech. For gas-line work or suspected heat-exchanger issues, professional service isn’t optional.
When the dealer blames “user error” — push for real diagnostics
We reviewed multiple owner narratives where a furnace problem was labeled “user error” until voltage and duct tests were documented. When you face friction:
- Ask for numbers: voltage at furnace under load, LP pressure during burn, temperature rise at registers.
- Request photos of corrected ducting or return-air openings.
- Escalate to the component manufacturer (furnace brand) if dealer support stalls. Keep detailed logs of failures and service attempts.
- Check complaint venues for similar reports to guide your ask. For example, search the BBB for complaint themes: BBB complaints about Furnace problems RV.
Owner-reported red flags (summarized)
- Recurrent board replacements without voltage or airflow corrections.
- Furnace works on shore power but not boondocking — often a voltage or wiring gauge issue.
- Heat in some rooms but not others — missing/blocked duct, collapsed flex, or poor routing.
- Overly hot registers — hinting at low airflow and impending limit trips.
Do any of these sound familiar? Tell us which red flag you’ve faced and what the final fix was so others can avoid the same loop.
Hydronic systems: prevention beats repair
- Annual service is not optional for diesel burners: nozzle, filter, combustion chamber cleaning, and electrode setting.
- Fuel quality matters — if possible, run fresh diesel and avoid long idle storage. Additives per manufacturer guidance can help mitigate coking.
- Bleed and balance loops after any service or if a zone runs cold.
- Altitude adjustments — consult your brand’s guidance; some require specific kits or derating above certain elevations.
Myths vs. facts
- Myth: “The furnace runs on AC power, so batteries don’t matter on shore power.” Fact: The furnace is a 12V appliance; weak batteries or a marginal converter still cause failures.
- Myth: “Closing vents forces more heat to other rooms safely.” Fact: Excessive vent closures reduce airflow and trigger limit trips, risking damage.
- Myth: “If it lights, the regulator is fine.” Fact: Under-load pressure can still be low, causing short cycling and poor burn quality.
- Myth: “New RVs don’t need furnace maintenance.” Fact: Installation errors and debris can affect brand-new units; verification is essential.
What manufacturers have improved — and what owners still report
- Improvements: quieter blowers, modulating heat on premium units, better diagnostic fault codes, and improved burner designs.
- Persistent issues: ducting shortcuts in cabinetry, sensitive control electronics paired with undersized wiring, and lack of return-air planning in certain layouts.
The bottom line: a well-installed furnace with verified voltage, proper propane pressure, and unrestricted airflow is highly reliable. Most repeat problems are preventable once the installation is corrected.
What to document for warranty and resale
- Photos of duct routing and return-air openings after corrections.
- Service notes showing LP pressures, voltage under load, and temperature rise.
- Parts invoices and labor descriptions, especially for control boards and motors.
- CO/LP detector installation dates and test logs.
This paper trail increases your leverage during warranty disputes and boosts resale confidence by showing a verified heating system.
Realistic maintenance schedule (propane systems)
- Before each season: clean intake/exhaust, check returns, verify detector function, run a 30-minute heat test.
- Every 1–2 years: burner/igniter inspection, blower cleaning, ducting inspection.
- Any time performance changes: recheck LP pressure and voltage under load; fix airflow issues immediately.
Research rabbit holes worth exploring
Video walkthroughs and long-form owner threads can save hours. For deep dives and model-specific tips, try:
- YouTube tutorials about Furnace problems RV — Look for videos covering your exact furnace model and fault codes.
- Good Sam community discussions on Furnace problems RV — Long-time owners often post step-by-step repairs.
Already fixed a tricky issue? Post your best resource or video link to help the next owner.
Pre-winter checklist you can do in one afternoon
- Charge-test batteries and confirm your converter’s output.
- Open every heat register and verify airflow. Fix any cold vents.
- Vacuum returns and under-cabinet spaces; remove obstructions.
- Inspect exhaust/intake and re-secure insect screens.
- Run a full heat cycle from cold for at least 30 minutes and note any short cycling or smells.
- Test CO/LP detectors and replace if out of date.
If you must camp while troubleshooting
- Carry a backup heat source rated and safe for RV use, such as an electric ceramic heater on shore power. Never use cooking appliances for heat.
- Ventilate even in cold weather to prevent condensation and maintain air quality.
- Monitor with a CO alarm and keep a fire extinguisher accessible.
Key takeaways: how to break the repair-repeat cycle
- Measure, don’t guess: voltage at the furnace under load, LP pressure under load, and temperature rise.
- Fix the system, not just the symptom: repair ducting, improve returns, secure grounds, and document changes.
- Service schedules matter: annual checks prevent the biggest failures, especially for hydronic burners.
- Escalate with data: use photos, readings, and service logs to get warranty action.
What finally solved your furnace issue? Share your fix in the comments so other RVers can benefit.
Owner voices: patterns we see across complaints
Summarizing recurring owner concerns from public forums and review sites:
- “Three tries then shutdown.” A classic ignition/verification cycle failure — often low voltage or airflow, sometimes LP pressure or electrode gap.
- “Works great at the dealer, fails in the mountains.” Altitude and colder batteries expose marginal systems; dealers often test at low load and sea level.
- “New coach, multiple boards.” Control boards die because the upstream problem (bad ground, voltage drop, blocked ducts) was never corrected.
If you’ve lived through one of these scenarios, tell us what the dealer missed so others know what to check first.
Final word: heat you can trust starts with installation you can verify
The RV furnace isn’t mysterious: clean 12V power, correct propane pressure, proper combustion, and unimpeded airflow. When those are right, even basic furnaces perform reliably in severe cold. When they’re wrong, swapping parts wastes time and money.
Use this report to ask sharper questions, demand measurements, and document fixes. You’ll sleep warmer—and help other owners by sharing what you learn.
Tell the community what happened to your furnace
Which symptoms did you face, what tests did you or your tech run, and what actually solved it? Real stories and measured data points help the next RVer fix their heat faster. Add your comment below.